Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 38 of 101
100518832 – Rev. B
selected the new value will not be saved, and the previous value will be
retained
8.7.2.7
Press the Left (
) Arrow Button to escape to the system setup menu
screen
8.7.3
Set Startup Delay –
8.7.3.1
Startup delay is how
many seconds after
boot-up that the
systems waits to turn
on the compressor. This is useful for multi-dryer setups where
powering all the compressors simultaneously might trip a breaker
8.7.4
Reset Compressor Total Hours –
8.7.4.1
Compressor total hours is the number of compressor runtime hours
since startup or the last time the compressor time counter was reset.
The dryer will display an alarm when this counter has reached 2,000
hours, signaling it is the recommended time to perform preventative
maintenance. When the compressor total hours are reset, the counter
will return to zero
8.7.4.2
From the system setup
menu screen, press the
Up (
) & Down (
)
Arrow Buttons to
navigate between the system setup options to locate “RESET
COMPRESSOR TOTAL TIME”
8.7.4.3
Press the Enter (●) button to enter the change value screen
8.7.4.4
Press the Right (
) & Left (
) Arrow Buttons to toggle between
YES / NO
8.7.4.5
Press the Enter (●) button on the desired value
Содержание BD210WLP Series