Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 70 of 101
100518832 – Rev. B
9.11.3
Turn knob clockwise
until Outlet Pressure
(
OUTP
) reading climbs
over the high outlet
pressure threshold (7.5
PSI, 51.7 KPa default).
After one (1) minute, the
High-Pressure Alarm
should appear on the display.
9.11.4
Turn Outlet Pressure
Regulator knob
counterclockwise until Outlet
Pressure (
OUTP
) reading
lowers to the reading recorded
in step 9.11.1
9.11.5
Tighten the retaining nut to
lock the setting in place