Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 86 of 101
100518832 – Rev. B
13.4 Air
Dryer Won’t Power ON
Possible Cause
Check
Corrective Action
POWER
Switch in
OFF
position
Verify
POWER
switch
is in the
ON
position
(section 8.4 )
Turn
POWER
switch
to the
ON
position
(section 8.4 )
No incoming voltage to
air Dryer
Measure incoming
voltage (section 9.4 )
Troubleshoot facility
power supply to air
Dryer
CAUTION!
Depressurizing the air Dryer may be necessary before performing
certain procedures.
NEVER
remove pressure sensing tubes from
the Control Board without depressurizing the air Dryer first, or
damage to the Control Board will occur.
IMPORTANT!
Performing procedures not described in this User’s Guide or
installing components not supplied by RFS is NOT
RECOMMENDED AND MAY VOID THE WARRANTY.
CAUTION!
Do not test the Humidity Sensor with an ohm meter or apply
any DC voltage.
This will render the Humidity Sensor defective.
WARNING!
High Noise
. RFS air-dryers are meant to be installed in an
unattended area.
CAUTION!
Observe precautions for handling
Electrostatic Sensitive Devices.
Содержание BD210WLP Series
Страница 2: ......