Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 36 of 101
100518832 – Rev. B
8.6.7
High Duty Cycle Alarm –
Occurs when the duty cycle rises above the alarm set point. The duty cycle is
calculated based on the previous two compressor last run time values.
See section 0for troubleshooting information.
8.7 Adjusting & Resetting Dryer Set Points
Dryer Set Points are simply limits programmed for a specific reading. Once this limit
is reached (or exceeded) this results in an alarm for that reading. Each of these set
points is factory programmed with a default value based on typical usage of the air
Dryer. Many of the set points for Dryer alarms can be modified to levels more
closely based upon your specific application.
NOTE
: Reference Appendix Section 14.3 for Limits and Defaults.
8.7.1
Navigating the Setup Menus
–
8.7.1.1
From any of the home
screens, press the Up (
)
Arrow Button to access
the setup menu screen
8.7.1.2
Press the Up (
) & Down (
) Arrow Buttons to navigate through the
available setup screens until the underscore appears underneath the
desired setup menu screen. The Setup Menu map is as follows:
System Setup
o
Set Alarm Delay
o
Reset Compressor Total Time
o
Reset To Factory Default Values
o
Set Current Date
o
Set Current Time
Alarm Setup
Содержание BD210WLP Series
Страница 2: ......