9.8.3
Depressurize air Dryer (see section 8.3.3)
9.8.4
Verify the compressor turns on when the tank pressure (
TANK
) falls to
20
PSI
(
137.9 KPa)
.
9.8.5
Reconnect air hose.
If the Compressor Cycling fails either test described, it indicates a problem with
the Control Board which will need to be replaced. See sections 11.1 for part
detail and 0for ordering information.
9.9 Testing High Compressor Last Run Time Alarm
CAUTION
: Be careful when removing Air hose. System is pressurized.
NOTE:
For this test, allow the Display Screen to cycle through the information
screens.
9.9.1
Start timing when the compressor turns on.
9.9.2
Depressurize air Dryer (
See sections 8.3 for detail).
This prevents the compressor from shutting down.
When the compressor runs for 5:00 minutes (unless adjusted to a different
Set Point by the user), a High Compressor Last Run Time (
LAST RUN
)
alarm should appear on the System Screen.