Radio Frequency Systems
BD210WLP Series Air Dryer User’s Guide
Page 64 of 101
100518832 – Rev. B
9.6.2
Use a Voltmeter to measure
the AC voltage across the set
of “
VALVE
” terminals. The
voltage reading should
alternate between
110 - 125
VAC
for the BD210WLP or
208 - 253 VAC
for the
BD212WLP and zero voltage
approximately every 60
seconds as the timer cycles.
If the voltage does not measure approximately the same as the incoming system
voltage the Cycle Timer could be defective. See sections 11.2 for troubleshooting
information.
9.7 Testing Air Dryer Fan
NOTE:
To test the fan, the cabinet temperature must be above 90
F (32
C).
9.7.1
Locate the fan exhaust on
the rear of the unit.
9.7.2
Place your hand outside the
Dryer to feel for air being
blown outwards.
NOTE:
Fan will turn OFF when the cabinet temperature is below 80
F (27
C).
If the fan is not blowing air outwards as described:
Verify the cabinet temperature is above 90
F (32
C).
Содержание BD210WLP Series
Страница 2: ......