Regency Horizon® HZ40E-10 Gas Fireplace
|
45
|
45
installation
OPTIONAL FAN INSTALLATION - EXISTING INSTALL
120 Volt AC power is needed for the fan switch and blower. The fan can
be hard wired if desired.The receptacle box should be installed on the left
hand side of the unit by a qualiied electrician.The neutral (wider) slot of the
polarized receptacle should be at the top (see page 41 for wiring diagram).
Unit must be grounded at all times. Do not cut the ground terminal off
under any circumstances.
1.
Shut off
the
gas and power supply to the unit.
2.
Remove the faceplate, mesh guard, enamel panels (if installed) and the
glass door. (See the manual for detailed instructions)
3.
Remove the inner panels - reverse of "Inner panel Installation" in the
installation manual.
4.
Remove the burner tray cover by lifting up and out as shown below.
* Prior to removing burner - remove crystals, pebbles, spa stones and inner
panels - if installed.
5.
Loosen 3 screws at the back of the burner to release it.
6.
Remove the burner by sliding it to the right - then lift out.
7.
Remove the left access plate by undoing the 8 screws - see locations
below.
8.
Remove the valve tray by undoing the 8 screws - see locations below.
Location of screws on access plate
9.
Manoeuvre fan through left access panel opening.