Regency Horizon® HZ40E-10 Gas Fireplace
|
31
|
31
installation
Flex Liner
Exhaust
Flue
A maximum
of two certified
joiner kits
may be used
per length.
#948-305
35 ft (11m)
Air Intake
Co-linear DV
Vertical Termination
Cap # 946-529
Co-Linear
Flex
Adapter
with Kit#
946-563
Outer
Pipe
with Kit#
946-563
Inner Pipe
Adapter
with Kit#
946-563
Rigid Pipe Adapter
# 510-994
Pipe Length
45 Elbow
o
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium lex running
the full length of the chimney. See the "Venting
Arrangements - Vertical Terminations" Section for
minimum and maximum heights.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563 Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510-994
Rigid Pipe Adaptor
46DVA-E45 45
o
Elbow
Alternate Approved Caps
46DVA-VC Vertical Termination Cap
46DVA-VCH High Wind Cap
46DVA-GK 3" Co-linear Adapter with lashing
Masonry chimneys may take various contours which the lexible liner will accommodate. However,
keep the lexible liner as straight as possible
, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE SERV-
ING A SEPARATE SOLID FUEL
BURNING APPLIANCE.