COPY OF SAFETY DECAL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, lexible con
-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli
-
ances individual manual shut-of must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
412
412
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles /
D gagement
inim
e
at riaux ombustibles
é
s m
aux d s m é
c
Serial No./ No de s rie
é
919-361
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Listed:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
CANADA and U.S.A.
Certified for/Certifi e pour:
é
Tested to:
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2014
Conforms to:
14
CSA 2.33-20
Certified to:
Fan (Part #
-917)
258
/Ventilateur (pièce n°258-917)
Electrical supply /
lectrique 115VAC, 1.13 A, 60Hz.
Alimentation é
Made in Canada/ Fabriqu au Canada
é
Duplicate S/N
(
See Instruction Manual for
detailed instructions)
APPAREIL FONCTIONNANT AU GAZ PROPANE
Mod le HZ40E-LP
è
10
PROPANE GAS: Model HZ40E-LP10
NATURAL GAS: Model HZ40E-NG10
Minimum supply pressure
Manifold pressure
Orifice size
Maximum input
Minimum input
Altitude
APPAREIL FONCTIONNANT AU G
NATUR L
AZ
E
Mod le HZ40E-NG
è
10
5.0"
WC/C.E. (1.25kPa)
3.5"
WC/C.E. (0.87kPa)
# 0
DMS
4
26
7.61
,000 Btu/h
(
kW)
18
5.28
,000 Btu/h
(
kW)
0-4500 ft/pi
(0-1372m)
11
WC
(2.73 kpa)
10"
WC/C.E. (2.49kPa)
# 5
DMS
3
25 5
7.47
, 00 Btu/h
(
kW)
21
6.15
,000 Btu/h
(
kW)
0-4500 ft/pi
(0-1372m)
Minimum supply pressure
Manifold pressure
Orifice size
Maximum input
in
M imum input
Altitude
D
E
F
A
B
C
Side Walls/Murs latéraux
A
8 (203mm)
Ceiling/Plafond
B
(
mm)
22
559
Min. Mantel Height/Hteur min. manteau
C
" (
mm)
17
432
Max. Mantel Depth/Prof. max. manteau
D
1
(
mm)
3
330
Alcove Width/Largeur alcôve
E
" (1524mm)
84
Alcove Depth/Prof. alcôve
F
36" (
mm)
2134
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles.
Cet appareil doit être utili
uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les
sé
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si une trousse certifié est utilisé .
e
e
This vented gas fireplace heater is not for use with air filters.
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
DOIT ÊTRE
É
VITRÉES
UTILIS UNIQUEMENT AVEC LES PORTES
CERTIFIÉES AVEC L'APPAREIL
4001172
For Use Only with Barrier
258 013 Follow installation instructions. Utiliser uniquement avec un écran de protection (n°258 013). Suivre les consignes d'installation.
(Part #
-
)
-
Pression d'alimentation minimum
Pression de sortie (manifold)
Taille de l orifice
D bit alorifique maximum
c
et
é
c
D bit alorifique minimum selon
é
l'altitude
Pression d'alimentation minimum
Pression de sortie (manifold)
Taille de l orifice
D bit alorifique maximum
c
et
é
c
D bit alorifique minimum selon
é
l'altitude
NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC