Page 1 of 15
®
Unit 4, Kimpton Trade & Business Centre
Minden Road, Sutton, Surrey, SM3 9PF
Tel: 020 8254 6802
USE & MAINTENANCE INSTRUCTIONS
FOR NU-FLAME FIREBOXX SYSTEM (NATURAL GAS & LPG)
FITTED WITH EVOLUTION
PLUS
BURNER. FOR DECORATIVE PURPOSES ONLY
NATURAL GAS MODELS: F350N fitted with an N2R+ (350) Evolution
Plus
Burner
F500N fitted with an N4R+ (500) Evolution
Plus
Burner
F720N fitted with N3R+(x2) (720) Evolution
Plus
Burners
LPG MODELS:
F350L fitted with an L2R+ (350) Evolution
Plus
Burner
F500L fitted with an L4R+ (500) Evolution
Plus
Burner
F720L fitted with L3R+(x2) (720) Evolution
Plus
Burners
GENERAL
a.
This fire must be installed by a properly qualified (in accordance with National & Local Regulations) Installation Engineer.
b.
The connection of this appliance, and ventilation requirements (if any) are to be according to National & Local Codes.
c.
The chimney should be swept before the appliance is installed.
d.
Open fires are a hazard; it is recommended that a guard be fitted to provide protection for children, the elderly or infirm. (See
National & Local Regulations if any.)
e.
This appliance is intended for decorative purposes only.
f.
Do not throw rubbish on, or attempt to burn any materials on this appliance. Any debris or foreign matter must be removed
from the fire.
g.
The appliance should be serviced by a qualified engineer every 12 months.
h.
The Thermatronic Control System is a battery operated gas fire control system that uses a microprocessor to provide the
working sequences needed by the fire, and when used with an oxypilot has all the safety features required by law and CE
approval.
i.
Commands are accepted by the microprocessor when buttons are pressed. An audible beep means that the command is
received, and the push button should immediately be released.
IMPORTANT NOTES
a.
This appliance is fitted with an oxygen depletion sensing system, which automatically shuts off the gas supply to the main
burner if the oxygen level in the room is depleted, due to a lack of primary air, or obstructed flue that would lead to incomplete
combustion of the gas.
b.
In the event that the fire shuts down due to any reason, attempt to restart it. If there is a continuing problem call in a properly
qualified specialist engineer.
c
. There are no user replaceable parts in this appliance except the 4 # AA batteries.
d.
The Fireboxx is supplied with batteries in a separate box that has a long lead which plugs into a socket on the standard
electronics/battery box.
e
. This battery box is accessed at the left hand end of the Fireboxx (beneath a removal cover plate) and positioned with the
connection lead connector at the top. Ensure that the lead wire does not contact the end of the burner pan by tucking the lead
wires between the battery box and the left hand end of the Fireboxx, as shown on the drawing on page 6.
f
. On no account put batteries into the battery compartment of the receiver box. They must only be placed in the battery box
situated at the left hand end of the Fireboxx, as shown on the drawing on page 6.
g.
Regularly inspect the purpose provided room ventilator (if fitted) to check that it is free from any obstruction.
h
. The chimney should be regularly checked to ensure that all the products of combustion are entering the flue & that there is no
build up of soot. If there is, the appliance must be cleaned.
i
. Do not cover the ventilation holes in the top plate grille with fuel bed or any other material.
IMPORTANT NOTE
Simulated crushed rock, simulated pebbles, simulated
logs, or simulated driftwood, manufactured from
special materials, are supplied with this appliance.
Do not use real crushed rock, pebbles, logs or
driftwood, as this is dangerous. If the simulated
crushed rock, simulated pebbles, simulated logs or
simulated driftwood need renewing please obtain
suitable replacements from a
Nu-Flame stockist.
Revision 8/12/18