background image

 

 

Page 6 of 15 

 

Содержание F350L

Страница 1: ...ygen depletion sensing system which automatically shuts off the gas supply to the main burner if the oxygen level in the room is depleted due to a lack of primary air or obstructed flue that would lead to incomplete combustion of the gas b In the event that the fire shuts down due to any reason attempt to restart it If there is a continuing problem call in a properly qualified specialist engineer ...

Страница 2: ...ries from the Receiver Box do not use metal tools to do this wait for 1 minute and then refit the batteries Wait for another minute and then point the handset at the fire and press the red off button Wait for another minute and then start the fire as normal If the fire does not start repeat the resetting procedure If the fire still does not work a Full Reset can be tried see below Note If an exten...

Страница 3: ... ENGINEER IMPORTANT BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCTIONS SHOULD BE KEPT IN A SAFE PLACE FOR FUTURE REFERENCE AND SERVICING DETAILS PRIOR TO INSTALLATION ENSURE THAT THE GAS TYPE PRESSURE ARE AS STATED ON APPLIANCE DATA PLATE SIMULATED CRUSHED ROCK SIMULATED PEBBLES SIMULATED LOGS OR SIMULATED DRIFTWOOD MANUFACTURED FROM SPECIAL MATERIALS ARE ...

Страница 4: ... important to ensure that the fire is not subjected to intermittent flue downdraught which can blow flames gas down to the underside of the burner and cause overheating of the electronics ADDITIONAL ROOM VENTILATION THE CONNECTION VENTILATION REQUIREMENTS IF ANY INSTALLATION OF THE APPLIANCE MUST BE IN ACCORDANCE WITH NATIONAL REGULATIONS AND LOCAL CODES IF IN ANY DOUBT WITH REGARD TO ANY VENTILAT...

Страница 5: ...ut a gas soundness check You can use the test point connection on the test point elbow inlet connection for your manometer Inlet Pressure 20mbar n Replace the top grille and position the battery cover plate as shown in the drawing on page 6 ARRANGEMENT OF THE FUEL BED FILL a The burner tray is supplied with the burner already fixed in place i Cover the burner slot with Sellotape or similar to prev...

Страница 6: ...Page 6 of 15 ...

Страница 7: ...ox do not let the lead terminals touch any metal parts because voltage is still stored in the capacitors which can cause a short circuit FULL RESET TO BE USED IF A REPLACEMENT HANDSET IS OBTAINED NOTE On some burners such as the Fireboxx and sunken burners it is not possible for the user to access the Receiver Box to carry out a Full Reset If the user cannot access the reset button on the Receiver...

Страница 8: ...Page 8 of 15 ...

Страница 9: ...Page 9 of 15 ...

Страница 10: ... MATERIAL IS REPLACED USE ONLY MATERIAL SUPPLIED BY THE MANUFACTURER FINER GRANULE SIZES ARE NOT SUITABLE Note SEEK EXPERT ADVICE IF YOU ARE UNSURE OF ANY POINTS REGARDING THE SAFE USE OF THIS APPLIANCE FAULT FINDING GUIDE SYMPTOMS AND POSSIBLE CAUSES 1 NO SPARK Pilot light damaged or too far away from Electrode or too close Electrode retaining lock nut has become loose and needs to be tightened I...

Страница 11: ...sary in order to fully comply with CE approval Note It is a condition of the warranty that you do not return any parts to us unless we request you to do so For example if we request that the burner only is returned and you send the entire appliance the fuel bed and other items could be damaged of lost during the return delivery to us We will not be liable for any such breakages or losses Under no ...

Страница 12: ... then if required adjust simulated pebbles to give desired effect MODEL F350 LAYOUT FOR RECOMMENDED F350 SIMULATED LOG OR DRIFTWOOD SET AVAILABLE FROM NU FLAME Identify the simulated logs driftwood in the set by comparing them to the drawings below and then lay them in accordance with the pattern shown Do not add further simulated logs driftwood BASE LAYER Lay the base layer of simulated logs drif...

Страница 13: ...lated logs driftwood TOP LAYER Run the fire for approximately 10 minutes and then if required adjust simulated logs or driftwood to give desired effect MODEL F500 LAYOUT FOR RECOMMENDED F500 SIMULATED PEBBLE SET AVAILABLE FROM NU FLAME Identify the simulated pebbles in the set by comparing them to the drawings below and then lay them in accordance with the pattern shown It is important to leave sp...

Страница 14: ...lated logs driftwood TOP LAYER Run the fire for approximately 10 minutes and then if required adjust simulated logs or driftwood to give desired effect MODEL F720 LAYOUT FOR RECOMMENDED F720 SIMULATED PEBBLE SET AVAILABLE FROM NU FLAME Identify the simulated pebbles in the set by comparing them to the drawings below and then lay them in accordance with the pattern shown It is important to leave sp...

Страница 15: ...roduct Fireboxx series Certificate Number 18GR0302 00 The objects of the declaration described above are in conformity with relevant harmonised legislation Regulation EU 2016 426 relating to appliances burning gaseous fuels The harmonised standards and technical specification have been applied Where the Essential Requirements of the GAR have been met and approved by Notified Body Responsible Test ...

Отзывы: