Regency Horizon® HZ40E-10 Gas Fireplace
|
13
|
13
installation
FRAMING DIMENSIONS
NOTE:
If not purchasing the optional steel stud kit - adhere to the same framing if purchasing steel studs elsewhere. The use of the optional kit is highly
recommended as it was designed speciically for the product to facilitate ease of installation.
Framing
Dimensions
Description
HZ40E
A
Framing Height
42” (1067mm)
B
Framing Width
49-7/8" (1266mm)
C
*
Framing Depth
*
C1
Horizontal Vent 21-3/16" (538mm)
C2
Vertical Vent 25-3/16" (640mm)
Vertical rise -terminating horizontal
D
Minimum Height to Combustibles
43-7/8" (1114mm)
E
Corner Wall Depth
61" (1549mm)
F
Corner Facing Wall Width
86-1/4" (2191mm)
G
Vent Centerline Height
36 - 1/4" (921mm)
H
Non-combustible facing height
17” (432mm)
I
Gas Connection Opening Height
2" (51mm)
J
Gas Connection Height
4 - 3/16" (106mm)
K
Gas Connection Inset
8 - 5/16" (211mm)
L
Gas Connection Opening Width
3 - 1/2" (89mm)
*
Framing depth measurement is noted with the nailing strips set as far forward on the irebox as possible.
The nailing strips can be adjusted back up to 3-1/4” to allow for varying thicknesses in non-combustible
material & wall inishes.
A
B
C
D
G
H
Non-Combustible
Facing
Metal Stud (Header)
Metal Studs
on edge
F
E
I
J
K
L
Flex or Rigid Pipe
Finished Floor
Drywall or
other facing
C2
C1
Note:
All other framing
around the perimeter may
be of wood construction.
Note:
Three horizontal
steel studs must be installed
after the unit is in position
and the venting, gas, and
electrical is installed. The
horizontal studs allow the
non-combustible wall board
to be attached and
supported.