REER S.p.A. - Via Carcano, 32 - 10153 Torino, Italy - Internet: www.reersafety.com - e-mail: [email protected]
36
8541205 - rev
.1 - 02/09/2019
Electrical connections/Operating modes
MUTING ENABLE
SAFEGATE can be configured in such a way that the muting cycle only starts after a signal of valid
MUTING ENABLE.
Pin 7 (MUTING_ENABLE) and 12 (STATUS) must be connected at power up as indicated:
MUTING
ENABLE (7)
STATUS (12)
SAFEGA
TE
ACTIVE ELEMENT
MUT_ENABLE
disabled
SAFEGA
TE
ACTIVE ELEMENT
EXT_MUTING
ENABLE SIGNAL
MUT_ENABLE
enabled
MUTING
ENABLE (7)
STATUS (12)
OPERATION
Disabled
The Muting cycle is activated
without considering
the MUTING ENABLE signal
Enabled
The Muting cycle is activated only with the correct transition of the MUTING ENABLE signal
(see figure below) and will terminate with the release of the last sensor.
Muting Enable active: correct Muting sequence