REER S.p.A. - Via Carcano, 32 - 10153 Torino, Italy - Internet: www.reersafety.com - e-mail: [email protected]
42
8541205 - rev
.1 - 02/09/2019
Electrical connections/Operating modes
Modelli SM, SMO
(2) SENSOR2
(3) 0VDC
(5) PE
(4) SENSOR1
(1) 24VDC
(2) SENSOR4
(4) SENSOR3
(5) PE
(3) 0VDC
0VDC (2)
OSSD1 (3)
OSSD2 (4)
PE (5)
SEL_B (11)
(1) 24VDC
(10) OVER1_RESTART
(9) OVERRIDE2
(8) EDM
(7) MUTING_ENABLE
(12) STATUS
(6) SEL_A
(1) 24VDC
N.C. (4)
(5) N.C.
(2) N.C.
(3) 0VDC
MUT_LAMP (1)
Modelli SMP, SMPO
(2) SENSOR2
(3) 0VDC
(5) PE
(4) SENSOR1
(1) 24VDC
(2) SENSOR4
(4) SENSOR3
(5) PE
(3) 0VDC
0VDC (2)
OSSD1 (3)
OSSD2 (4)
PE (5)
SEL_B (11)
(1) 24VDC
(10) OVER1_RESTART
(9) OVERRIDE2
(8) EDM
(7) MUTING_ENABLE
(12) STATUS
(6) SEL_A/Partial_Muting
(1) 24VDC
VBUS (4)
(5) USB-
(2) USB+
(3) 0VDC
MUT_LAMP (1)
Table 3
MAIN MALE CONNECTOR - M12 - 12 PIN
PIN
COLOUR
SIGNAL
IN/OUT
DESCRIPTION
ELECTRICAL LEVEL
1
Brown
24VDC
-
POWER SUPPLY 24 VDC
-
2
Blue
0VDC
-
POWER SUPPLY 0VDC
-
3
White
OSSD1
Output
STATIC SAFETY OUTPUTS PNP active high
4
Green
OSSD2
Output
5
Pink
PE
-
EARTH CONNECTION
-
6
Yellow
SEL_A
Input
MUTING CONFIGURATION Refer to
PARTIAL_MUTING
CONTROL PARTIAL MUTING The level of the
is decided through the configuration software
7
Black
MUT_ENABLE
Input EXTERNAL MUTING
ENABLE
Safegate considers the muting cycle correct if it
rising edge before the use of the sensors
8
Grey
EDM
Input FEEDBACK K1/K2
External contactors feedback
9
Red
OVERRIDE2
Input OVERRIDE REQUEST
Refer to the section
“OVERRIDE (pc programming)”, page 45
10
Violet
OVERRIDE1
Input
OVERRIDE REQUEST
Refer to the section
“OVERRIDE (pc programming)”, page 45
RESTART
RESTART INTERLOCK
11
Grey/ Pink
SEL_B
Input MUTING CONFIGURATION Refer to the section “SELECTION OF
12
Red/Blue
STATUS
Output SYSTEM STATUS
PNP active high
)
(
)
(