REER S.p.A. - Via Carcano, 32 - 10153 Torino, Italy - Internet: www.reersafety.com - e-mail: [email protected]
74
8541205 - rev
.1 - 02/09/2019
Configuration software
“Sequential” Muting
Î
Î
The activation of the Muting function occurs following the sequential interruption of the sensors
S1 and S2, and the sensors S3 and S4. If the pallet proceeds in an opposite direction the correct
sequence is: S4, S3, S2, S1.
Parameters
With_Enable:
If checked, it is possible to read the external
signal of
"MUT_ENABLE"
(Muting Enable). Otherwise, the
Muting function is always enabled. Enable can be of two types:
Enable/Disable and Enable Only. If you select it
"Enable/
Disable"
the Muting cycle cannot start if Enable is fixed at
24VDC or 0VDC but it is activated only with one rising edge, if
you want to disable the muting, the signal must be returned to
0VDC. In this way, the detected falling edge disables Muting in
any condition. If you select it
"Enable Only"
there is no way to
disable Muting over the entire duration of the function, but you
must always return Enable to 0VDC to allow a new rising edge
for the next Muting cycle (refer to the "Partial Muting" section).
Muting Timeout:
Allows you to set the time, variable from 10
sec to infinity, within which the Muting cycle must end, if, when
the cycle is not yet over, Muting is disabled immediately.
Sensor Filtering:
With non-homogeneous pallet materials
and possible "gaps" in the interruption of muting, this parameter allows filtering the drop of the sensor
signal leaving then the muting sequence unchanged. This parameter can be 500 ms or 1000 ms.
Position S2:
Not allowed.
Direction:
You can set the occupancy order of the sensors; if set BIDIR the occupation can take place in
both directions from S1 & S2 to S3 & S4 or reverse order; if you choose UP the occupancy order is: S1 &
S2 to S3 & S4 and eventually with DOWN the occupancy order is: S4 & S3 to S2 & S1.
Number Beams:
Makes it possible to select the number of beams that can be affected by Muting (if Partial
Muting is active).
Muting Closure:
It can be of two types CURTAIN and SENSOR. By selecting CURTAIN, muting closes at
the release of the protected gate, while with SENSOR, closure occurs after the release of the last but one
sensor.
External Lamp Control:
If selected, the Muting lamp is compulsory.