SAFEGATE DIAGNOSTIC - ERRORS
ERROR
FAILURE DESCRIPTION
ACTION
0 ÷ 25
Internal error
Return the barrier to ReeR to be repaired
34
35, 37
40, 47
49, 50
OSSD error
Verify connection of pins 3, 4 on the main connector
32, 33, 36,
38, 39, 41
42, 43, 44
45, 46, 48, 51
OSSD Internal error
Return the barrier to ReeR to be repaired
64 ÷ 73
Main board Internal error
Return the barrier to ReeR to be repaired
74, 75
Overcurrent on 24VDC
Verify max current consumption < 1,6A
76 ÷ 85
90
Main board Internal error
Return the barrier to ReeR to be repaired
86, 87
STATUS out error
Verify connection of pin 12 on the main connector
88
Overcurrent on auxiliary LAMP
Verify connection of pin 1 on the LAMP/USB connector
89
See 86, 87, 88
See 86, 87, 88
105, 106
Interfering Emitter detected
¾
Switch the position of the Active and Passive elements
¾
Move the interfering Emitter to avoid this illuminating the
Active element
¾
Shield the beams coming from the interfering Emitter using opaque
protections
128
Configuration error
Verify connection of pins 6, 11 on the main connector
129
Initial configuration modified
Verify connection of pins 6, 11 on the main connector
130
See 128, 129
See 128, 129
131, 132
With EDM active, initial PIN 8 status wrong
Verify connection of pin 8 on the main connector
133
Stucked EDM contact (closed)
Verify external contacts
134
Open EDM contact
Verify external contacts
135
See 133, 134
See 133, 134
136
OVERRIDE configuration error
Verify connection of pins 9, 10 on the main connector
137
Exceeded max number of Override requests
Turn off and on SAFEGATE
138
See 137
See 137
139
24VDC on STATUS output
Verify connection of pin 12 on the main connector
140
Overcurrent on STATUS output
Verify connection of pin 12 on the main connector
141
See 139, 140
See 139, 140
142
Error on Integrated lamp
Return the barrier to ReeR to be repaired
143, 144
Error on Auxiliary lamp
Verify connection of pin 1 on the LAMP/USB connector
146, 147
Muting sensors configuration error
¾
Verify muting sensors connection
¾
Verify position of sensor 2 with the software
¾
If no error is detected, return the barrier to ReeR to be repaired