REER S.p.A. - Via Carcano, 32 - 10153 Torino, Italy - Internet: www.reersafety.com - e-mail: [email protected]
30
8541205 - rev
.1 - 02/09/2019
Electrical connections/Operating modes
Table 1
MAIN MALE CONNECTOR - M12 - 12 PIN
PIN COLOUR
SIGNAL
IN/OUT
DESCRIPTION
ELECTRICAL LEVEL
1
Brown
24VDC
-
POWER SUPPLY 24 VDC
-
2
Blue
0VDC
-
POWER SUPPLY 0VDC
-
3
White
OSSD1
Output STATIC SAFETY OUTPUTS PNP active high
4
Green
OSSD2
Output
5
Pink
PE
-
EARTH CONNECTION
-
6
Yellow
SEL_A
Input
MUTING CONFIGURATION Refer to
7
Black
MUT_ENABLE
Input
EXTERNAL MUTING
ENABLE
Safegate considers the muting cycle correct if it
signal rising edge
before the use of the sensors
8
Grey
EDM
Input
FEEDBACK K1/K2
9
Red
OVERRIDE2
Input
OVERRIDE REQUEST
10
Violet
OVERRIDE1
Input
OVERRIDE REQUEST
RESTART
RESTART INTERLOCK
Refer to the table
11
Grey/ Pink
SEL_B
Input
MUTING CONFIGURATION Refer to the section
12
Red/Blue
STATUS
Output SYSTEM STATUS
PNP active high
Î
When connecting high inductive loads to OSSDs, use suitable voltage suppressors on the outputs.
In free protected area conditions, the Active Element provides a voltage of 24VDC on both outputs.
Therefore, the established load must be connected between both output terminals and the 0VDC.