Electrical connections/Operating modes
TEST FUNCTION
The SAFEGATE barrier system features an automatic self-diagnosis function that enables it to detect
response time malfunctions (this time is declared for each model).
This fault detection system is always active and does not require any external intervention.
SELECTION OF OPERATING MODES
Î
Configuration of the various modes of operation of the SMP/SMPO models is achieved thanks to the
SAFEGATE CONFIGURATOR software.
The incorrect setting of the Muting parameters by the operator compromises the safe operation of
the barrier.
EDM
The EDM function (external K1 / K2 control) can be enabled / disabled via software:
Hardware configuration
EDM (8)
OSSD2 (4)
SAFEGA
TE
ACTIVE ELEMENT
EDM enabled
EDM (8)
OSSD2 (4)
SAFEGA
TE
ACTIVE ELEMENT
EDM disabled
Software configuration
EDM disabled
EDM (8)
OSSD2 (4)
SAFEGA
TE
ACTIVE ELEMENT
EDM enabled
+24VDC
FBK K1
FBK K2
EDM (8)
OSSD2 (4)
SAFEGA
TE
ACTIVE ELEMENT
EDM enabled
+24VDC
FBK K1
FBK K2
EDM ACTIVATED
SAFEGATE awaits a signal with inverse logic to the condition of the external contactors:
¾
OSSD1 / OSSD ON: External contacts K1/K2 closed:
EDM = OPEN CIRCUIT
¾
OSSD1 / OSSD OFF: External contacts K1/K2 open:
EDM = CLOSED CIRCUIT
Connect the pin 8 of the main connector to the Active Element as shown above.
The time allowed to elapse from the activation of the OSSD outputs and the opening of the FBK contacts
must be the one indicated in the figure below.
¾
EDM reading delay
programming
¾
EDM enabled
SOFTWARE CONFIGURATION:
FBK K1/K2 reading delay programming:
Range allowed: 100ms to 1300ms (100ms steps).