The Muting function
C) 2 INTEGRATED CROSS MUTING SENSORS, FOR BI-DIRECTIONAL GATES (TX)
In this way, the two Muting sensors are each first on a different side of the vertical curtain.
This mode is unidirectional and is useful for protecting gates with pallet output.
Î
Î
The crossing point of the two Muting sensors must be placed inside the hazardous area to avoid
undesirable and dangerous activations of the Muting function.
The activation of the Muting function occurs after the simultaneous interruption (within max 4 sec) of
sensors S1 and S2. As long as both sensors remain busy, the Muting function continues. By releasing the
first of the two sensors, the Muting function is disabled.
This mode also allows selecting the maximum duration of the Muting condition (timeout) as 30 seconds or
9 hours.
Î
Î
Other timings are available with programmable programs.