Controls, care and maintenance
4.
Verify protected zone:
a) Interrupt with one opaque object every beam in the centre and then close to both the Active and Passive
Element.
b) Check that at each stage of the test object movement the red LED on the Active Element remains in any
case switched on and that the dangerous machine stops.
CARE AND MAINTENANCE
SAFEGATE does not require any specific maintenance work; however, periodic cleaning of the frontal
protection surfaces of the two devices is recommended.
Cleaning should be carried out with a damp cloth; In particularly dusty environments, after cleaning the
front surface, it is advisable to spray it with an anti-static product.
Î
In any case, do not use abrasive, corrosive, solvents or alcohol that could damage the part to be
wiped or wool cloth to avoid electrostatically loading the front surface of the curtain itself.
Î
Even a very fine groove of frontal plastic surfaces can increase the width of the beam of the light
curtain, thus compromising the effectiveness of detection in the presence of reflective lateral
surfaces.
Î
It is therefore essential to pay particular attention during the cleaning steps of the curtain front
window, particularly in environments where abrasive powders are present. (e.g. cement plants, etc.).