REER S.p.A. - Via Carcano, 32 - 10153 Torino, Italy - Internet: www.reersafety.com - e-mail: [email protected]
55
8541205 - rev
.1 - 02/09/2019
Light signals
LED
MEANING
Blue
Curtain programmed via USB
Orange
Communication with active PC
Blue
Weak signal (it can blink alternatively with orange)
Yellow
Curtain awaiting RESTART (clear gate)
Green
Normal operation (clear gate)
Red
Occupied gate
Red
Flashing
Detected failure (see “TROUBLESHOOTING”)
Yellow
Muting active
Yellow
Override active
Yellow
Flashing
Override request
Yellow
Sensor interrupted
Blue
Flashing
Orange
Flashing
No barrier programmation
Blue
Flashing
Orange
Flashing
Red
Flashing
Detected double programmation
(hardware and software)
LIGHT SIGNALS
SAFEGATE is equipped with an Active Element label with leds to signal
its operating condition in real time.
In addition SMO - SMPO models are equipped with a LED signal lamp
integrated in the upper cap.
Refer to the following tables to recognize active alarms.
ACTIVE ELEMENT SIGNALS (SM / SMO / SMP / SMPO)