29
ENGLISH
PARAMETERS
ATTACK
Adjusts the compressor attack time.
POST GAIN
Adjusts the output gain (useful to minimize the signal
attenuation due to compression).
HOLD
Adjust how long the compression is held after the audio
signal returns below the predetermined threshold.
DECAY
Adjusts the compressor release rate.
CURVE
Curve selection:
- Curve 1
- Curve 2
- Curve 3
BYPASS
Select either
On
(compressor bypassed) or
Off
(compressor
inserted).
AGC
(automatic gain control)
The automatic gain control can be useful to optimize the output level of an audio input
signal extremely variable.
The AGC operates in 5 ways and has two selectable different compressor/limiter modes:
1. NOISE GATE (input signal lower or equal to –70 dBu)
2. EXPANDER (input signal range: –70 to –40 dBu)
3. LINEAR (input signal range: –40 e –10 dBu)
4. COMPRESSOR (input signal range: –10 e –3 dBu in
mode 1
, –10 e +3 dBu in
mode
2
)
5. LIMITER (input signal above –3 dBu in
mode 1
or +3 dBu in
mode 2
).
MODE 1
MODE 2
Содержание MX 9502