19
ENGLISH
A
B
470 Ω
10 kΩ
46
FLEXCOM BUS IN:
data bus input (removable connector).
47
FLEXCOM BUS OUT:
data bus output (removable connector).
48
GENERAL PURPOSE INPUTS
12 logic inputs (removable connectors), of which the first 8 are monitored and the last 4
with opto-isolators.
T
he
lOgical
iNpuTS
9
TO
12
caN
be
acTiVaTed
bY
cONNecTiNg
The
24 V dc
49
OuTpuT
TO
each
lOgic
iNpuT
. p
OSSible
lOgic
STaTeS
:
iNacTiVe
/
acTiVe
.
LOGIC INPUT 1 ÷ 8 STATES:
SUGGESTED RESISTORS TO BE ADDED TO GET LINE MONITORING:
A
B
GPI
(1-8)
STATE
DETECTED RESISTANCE VALUE (R)
OPEN
Open line or too high resistance
R > 15 kΩ
SHORT
Short-circuit or too low resistance
R < 390 Ω
IDLE
Used logic input, but inactive
3.4 kΩ < R < 15 kΩ
ACTIVE
Activated logic input
390 Ω < R < 1.17 kΩ