Standard 30 MF
110-700
Operator and Service Manual
Edition:
1-3
4361.DOC010302 AUG18.DOCX
1.3.3
Electrical Data
Nominal Supply voltage
24 V DC
Nominal Power consumption
24 W
Interfaces
‐
2x CAN-bus
‐
2x Serial input (latitude, speed)
‐
4x Serial output
‐
2x Relais
(heading O. K. system fault)
‐
1x Analog rate of turn
‐
2x Ethernet (input and output)
1.3.4
Input Data
The Standard 30 MF can read and process the following signals via the data interfaces
and the Ethernet interfaces:
NMEA Speed from __VTG, __VBW, __VHW
NMEA Latitude from __GGA, __GLL, __GNS
NMEA Alert from CAM
Standard 30 MF provides two different methods for alert management. The first method is
based on alarms and acknowledgement according to IEC 61162-1. The second method
provides different priorities of alerts and alert escalations. This method was introduced
with Integrated Navigation Systems based on IEC 61924-2.
Inputs for alert management:
ACK, HBT according to IEC 61162-1 (via serial interface) or
ACN according to IEC 61924-2 (via Ethernet)