Standard 30 MF
110-700
Operator and Service Manual
Edition:
1-17
4361.DOC010302 AUG18.DOCX
1.4.4.2
Power Supply Sockets P1 and P2
Figure 1-8
Power Supply Plugs P1 and P2
The both 4-pin round plugs P1 and P2 on the device front are provided to connect
2 power supplies for redundancy.
Delivery of the Standard 30 MF includes two STD 30 power supply cables of type LKSM-
HF 2 x 1.5 mm², 0.6/1 kV for connection to the power supply. They are equipped with a
pre-mounted 4-pin socket. Each cable is approx. 3 m long.
The open ends of the connecting cables are fitted with ferrules for connection to a terminal
strip. They are labeled with pin number and signal name.
The pin assignments for P1 and P2 are shown in the following table.
Table 1-3
STD 30 Power Supply Cables P1 and P2, Pin Assignments
Pin No.
Signal
Cable Color
1
24V_1 / 2
brown
2
0V
blue
Pins 3 and 4 are not assigned.
Содержание Standard 30 MF
Страница 104: ...Standard 30 MF 110 700 Operator and Service Manual 4361 DOC010302 AUG18 DOCX 4 8 Edition 8 Intentionally left blank ...
Страница 106: ...Standard 30 MF 110 700 Operator and Service Manual 4361 DOC010302 AUG18 DOCX 5 2 Edition 8 Intentionally left blank ...
Страница 108: ...Standard 30 MF 110 700 Operator and Service Manual 4361 DOC010302 AUG18 DOCX 6 2 Edition 8 Intentionally left blank ...