2.3.5
CAN-Bus Termination
If the Standard 30 MF is connected to a CAN-Bus as the first or as
the last device, the CAN-Bus must be terminated using the 120 Ω
resistors (included in the delivery).
1. Connect the two 120 Ω resistors respectively to the CAN#1_H/CAN#1_L and
CAN#2_H/CAN#2_L signals at the cable terminal.
The CAN#1_H / CAN#1_L signals and the CAN#2_H / CAN#2_L
signals are respectively present at the free ends of pins 27 and 33 of
the STD 30 data cables N1 and N2.
2.3.6
Setting the CAN-Bus address
The CAN-Bus address for the Standard 30 MF is set with the external service
configuration tool
WinSCP
on a service PC (see chapter 2.4). Every CAN-Bus user must
have a unique address. The CAN-Bus address for gyro compasses can be set within a
range from 14 to 19.
The table below shows the agreement for the CAN-Bus addresses within a compass
system.
Table 2-1
CAN-Bus addresses within a compass system
Device(s)
CAN-Bus address
Operator Units
01 to 09
Sensors (GPS-compass)
10 to 13
Sensors (gyro compass)
14 to 19
Distribution Units
20 to 29
Gateway
56 and 57