Alerts are divided in different categories:
Category A
Alerts for which graphical information at the task station (such as Radar or ECDIS)
directly assigned to the function generating the alert is necessary, as decision support
for the evaluation of the alert-related condition. These alerts can only be acknowledged
at the task station.
Category B
2)
Alerts where no additional information for decision support is necessary besides the
information which can be presented at the CAM-HMI. These alerts can be
acknowledged at the task station or at the CAM-HMI.
Category C
Alerts that cannot be acknowledged on the bridge but for which information is required
about the status and treatment of the alerts (e.g. certain alerts from the engine).
2)
All alerts have the category
B
. Categories
A
and
C
are not used in this device.
Table 4-1
Alert List – Warning Symbols
Icon/Symbol
Description
Active – unacknowledged warning (flashing)
Active – silenced warning (flashing)
Active – acknowledged warning
Rectified – unacknowledged warning (flashing)
Table 4-2
Alert List – Caution Symbol
Icon/Symbol
Description
Caution