Standard 30 MF
110-700
Operator and Service Manual
4361.DOC010302 AUG18.DOCX
2-6
Edition: 8
2.3.3
Preparations
The Standard 30 MF is mounted directly to the vessel's structure on the floor or on the
ceiling. The surface must be plane. The tolerance in the area of the contact surface is
±2 mm.
If no attachment points for the Standard 30 MF have been prepared on the vessel side
yet, proceed as follows:
1. Select a suitable installation position on the floor or ceiling.
2. Mark attachment points at the installation position according to Figure 2-2.
‐
The maximum permissible deviation of the installation orientation from the pitch or
roll axis of the vessel after installation is ±6°. A heading correction factor for the
deviation will be defined during setting to work.
3. Drill holes with a diameter of 5.0 mm at the 4 attachment points.
4. Cut an M6 thread into each attachment drill hole.
Alternatively pre-install M6 stud bolts on which to mount the device.
Only if no ground connection point on the vessel side is provided at the installation
position, proceed the following steps:
5. Mark the point where to attach the ground connection on the vessel side at a
maximum distance of 150 mm from the ground connection on the Standard 30 MF.
The ground connection point on the vessel side may be an M6 bolt or
an M6 internal thread.
6. Install the ground connection point on the vessel side:
weld the M6 bolt to the prepared surface or
drill a hole with a diameter of 5.0 mm at the ground connection point and cut an M6
thread