Standard 30 MF
110-700
Operator and Service Manual
Edition: 8
2-17
4361.DOC010302 AUG18.DOCX
2.3.8.1
Calculating the Heading Correction Value
The heading correction value has to be entered during the setting to work procedure of
the Standard 30 MF after the settling phase has been completed.
2 values are required for the calculation:
pier heading P -> reference heading
value displayed on the Operator Unit I -> actual heading
The following applies for the algebraic sign of the heading correction
value:
If the set value
P
is in a clockwise direction from the actual value
I
on
the imaginary compass card, the algebraic sign is positive.
If the set value
P
is in a counterclockwise direction from the actual
value
I
on the compass card, the algebraic sign is negative.
Figure 2-7
Positive Correction Value
Figure 2-8
Negative Correction Value
Table 2-2
Example Calculations for the Heading Correction Value
P
Reference
Heading
I
Actual
Heading
K
Heading Correction Value
Note
179.1°
176.3°
2.8°
See figure 2-7
87.1°
90.3°
-3.2°
See figure 2-8
359.1°
1.7°
-2.6°
See figure 2-8
2.1°
358.5°
3.6°
See figure 2-7
P in clockwise direction from I
P
I
P in counterclockwise direction from I
P
I