Standard 30 MF
110-700
Operator and Service Manual
4361.DOC010302 AUG18.DOCX
1-14
Edition: 8
Pin No.
Wire Label
Function /
Factory Settings
16
16 K2 NO
Status relay "Heading OK"
(normally open)
23
13 K2 CO
Status relay "Heading OK"
(common)
17
17 K2 NC
Status relay "Heading OK"
(normally closed)
9
9 Rx+ 3
not used
15
15 Rx- 3
8
8 Tx+ 3
Serial output 3 (Port 3)
Telegrams: HEHDT, HEROT
Baudrate: 38400bd
Update rate: 50Hz
13
13 Tx- 3
14
14 RS3 GND
Ground for serial port 3
2
2 STAT1 IN 5VDC
not used
1
1 STAT1 IN 0VDC
35
35 Rx+ 2
Serial input 2 (Port 2)
for speed
Telegrams:VHW, VBW, VTG
Baud rate: 4800bd
31
31 Rx- 2
34
34 Tx+ 2
not used
29
29 Tx- 2
30
30 RS2 GND
Ground for serial port 2
Pins 4, 18, 19, 20, 24, 25 and 26 at socket N1 are not assigned.