Standard 30 MF
110-700
Operator and Service Manual
4361.DOC010302 AUG18.DOCX
2-22
Edition: 8
‐
The menu item will be highlighted yellow.
5.
Press the
Set
key on the Operator Unit.
‐
The
SERIAL OUTPUT DATA SETUP
dialog appears.
Figure 2-13
Dialog SERIAL OUTPUT DATA SETUP – COURSE BUS
6. Press
Page
key to select desired port.
The dialog can be left at any time via the
Exit
menu item at the
bottom right of the picture.
In the
PROTOCOL
line, the two further dialogs for setting the NMEA
telegrams (
NMEA
) or the NMEA alert messages (
NMEA ALERTS
)
can be opened.
For Course Bus Adjustments
1. In the
PROTOCOL
line, select the
COURSE BUS
protocol with the arrow keys.
2.
Press the
Set
key on the Operator Unit.
‐
The dialog for setting the baud rate for the course bus appears (Figure 2-13).
‐
The
COURSE BUS
menu entry is displayed in orange.
3. Select the desired baud rate for transmission on the
course bus
with the arrow keys.
‐
The selected value will be highlighted yellow.