SECTION 2: I
NSTALLER
R
ESPONSIBILITY
7 of 143
2.1 Corrosive Chemicals
Rapid Engineering LLC cannot
b
e responsi
b
le for
ens
u
ring that all appropriate safety meas
u
res are
u
ndertaken prior to installation; this is entirely the
responsi
b
ility of the installer. It is essential that the
contractor, the s
ub
-contractor, or the o
w
ner identifies
the presence of com
bu
sti
b
le materials, corrosi
v
e
chemicals or halogenated hydrocar
b
ons* any
w
here
in the premises.
* Halogena
t
e
d
Hy
d
rocarbons
are a family of chemical
compounds characterized by the presence of halogen elements
(fluorine, chlorine, bromine, etc.). These compounds are
frequently used in refrigerants, cleaning agents, solvents, etc. If
these compounds enter the air supply of the burner, the life span
of the air turnover unit components will be greatly reduced. An
outside air supply must be provided to the burners whenever
the presence of these compounds is suspected. Warranty will
be invalid if the air turnover unit is exposed to halogenated
hydrocarbons.
2.2 Re
q
uired E
q
uipment and Materials
When lifting of the eq
u
ipment is req
u
ired, the
installing contractor is responsi
b
le for s
u
pplying or
arranging for the appropriate lifting eq
u
ipment so that
the air t
u
rno
v
er
u
nit and accessories may
b
e placed
in a safe manner.
The q
u
alified installing / ser
v
ice technician is
responsi
b
le for ha
v
ing the appropriate eq
u
ipment
and materials for the safe installation and start-
u
p of
an indirect-fired air t
u
rno
v
er
u
nit. Tools and materials
req
u
ired to commission the eq
u
ipment incl
u
de,
bu
t
are not limited to, the follo
w
ing:
• Vario
u
s scre
w
dri
v
er types and sizes
• Vario
u
s adj
u
sta
b
le
w
renches
• Torq
u
e
w
renches
• Pipe
w
renches sized appropriately for the gas
train components
• Drill motor and
v
ario
u
s drills
• U-t
ub
e manometer 0 to 6"
w
c (0 to 14.9 m
b
ar)
• Gas press
u
re ga
u
ge 0 to 30"
w
c
(0 to 74.7 m
b
ar)
• Gas press
u
re ga
u
ge to s
u
it
bu
ilding s
u
pply
press
u
re conditions
• Oil press
u
re ga
u
ge 0 to 300 PSIG
(0 to 20
b
ar)
• Com
bu
stion analyzer
• Stack thermometer
• Oil smoke tester
• Volt meter
• Clamp style ammeter
• Belt tension ga
u
ge
CAUTION
Product Damage Hazard
Do not use equipment in area containing
corrosive chemicals.
Refer to appropriate Material Safety Data
Sheets (MSDS).
Failure to follow these instructions can result
in product damage.
Содержание 7500 136
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 12: ......
Страница 33: ...SECTION 6 LIFTING AN AIR TURNOVER UNIT 21 of 143 FIGURE 10 Lifting an Air Turnover Unit Base Section...
Страница 36: ...7500 SERIES INSTALLATION OPERATION AND SERVICE MANUAL 24 of 143 FIGURE 12 Air Turnover Unit Sections Schematic...
Страница 67: ...SECTION14 ELECTRICAL 55 of 143 FIGURE 38 Wiring Diagram Key...
Страница 115: ...SECTION 15 SEQUENCE OF OPERATION 103 of 143 FIGURE 83 Wiring Subbase and Sequence Chart for RM7897 Burner Control Module...
Страница 156: ......