13
Locations 155-170: Assigning Special Characteristics For Zones 1-16
Locations 155 through 170 are used to assign zone characteristics for zones 1 through 16. Location 155 is for zone
1 and location 170 is for zone 16. Each zone can have any or all of the following characteristics regardless of the
zone type selected in locations 139-154, excluding
Fire
zones, which cannot have
Bypass Capability
enabled.
Factory default is "12" for each of these locations, meaning that
Zone Bypass Capability & Entry-Guard
is enabled,
and the other characteristics are not enabled. To include other characteristics, add their value, and program the sum
in the appropriate location. See the table below for zone characteristics and their corresponding values.
VALUE
CHARACTERISTIC
1
Fast Loop Response (200mS)
2
Group Bypass Zone
4
Entry-Guard Zone
8
Zone Bypass Capability
Example 1
- To add
Group Bypass (Value=2)
to
Zone Bypass Capability (Value=8)
for zone 10 (location 164),
add the value of the two characteristics (2 + 8 ="10"), and program the sum of "10" in location 164.
Example 2
- To enable
ALL
characteristics for zone 10, add the value of all characteristics (1 + 2 + 4 + 8 = "15"),
and program the sum of "15" in location 164 (zone 10 characteristics location).
Example 3
- To disable all characteristics and create a
Non Bypassable Zone
, program a "0" in the appropriate
location.
NOTE: Group Bypass zones MUST also have zone bypass capability programmed so they will bypass!
Locations 171-186: Assigning Audible Characteristics For Zones 1-16
Locations 171-186 are used to assign the audible characteristics of each zone 1 through 16. Location 171 is for
zone 1 and location 186 is for zone 16. To determine the appropriate data for these locations, refer to the chart below
and add the sum of the corresponding values to arrive at the correct data for these locations. For all zones except
zone 2, factory default is "13" (1+ 4 + 8 = "13"). Factory default for zone 2 is "5" (1 + 4 = "5"). The
Chime
feature was
not selected because it is usually undesirable on interior/follower zones which is the factory default type for zone 2.
This means that all 16 zones will create a yelp siren output and a keypad sounder output when an alarm is created.
To select the audible characteristics for any zone, add the values of the audible characteristics from the table below,
and program the sum in the appropriate locations 171-186. If you wish for the zone to be
Silent
, program a "0" in
the appropriate location. NOTE: If a
Fire
zone type is selected in locations 139-154, standard fire zone
characteristics will override any selection made for a zone in this section.
VALUE
AUDIBLE CHARACTERISTICS
0
Silent
1
Yelp Siren Audible
2
Steady Siren Audible
4
Keypad Sounder Audible
8
Chime Enable