29
The following locations allow for the transmitting of variable bypass report codes in zone blocks of eight (8).
If a code is selected for zones 1-8 in location 368, it will apply to all zones unless individual codes are
selected for locations 369-371. If location 368 contains a "0", no bypass reports will be sent. If enabled,
bypass reports will be made at the end of the exit delay for non-24 hour zones. 24 hour zones will report
a bypass immediately. When a bypass is removed, a "Restore" will be reported if "Restore" is enabled in
location 364.
Location 368: Zone Bypass Code For Zones 1 Thru 8
Location 369: Zone Bypass Code For Zones 9 Thru 16
Location 370: Zone Bypass Code For Zones 17 Thru 24 (When Using Expansion System)
Location 371: Zone Bypass Code For Zones 25 Thru 32 (When Using Expansion System)
The following locations allow for the transmitting of variable trouble report codes in zone blocks of eight (8).
If a code is selected or zones 1-8 in location 372 it will apply to all zones unless individual codes are selected
for locations 373-375. If location 372 is "0", no trouble reports will be sent.
Location 372: Zone Trouble Code For Zones 1 Thru 8
Location 373: Zone Trouble Code For Zones 9 Thru 16
Location 374: Zone Trouble Code For Zones 17 Thru 24 (When Using Expansion System)
Location 375: Zone Trouble Code For Zones 25 Thru 32 (When Using Expansion System)
Location 376: Programming For AC Power And Low Battery Restore Code
If this location contains a "0", no AC Power or Low Battery restorals will be sent. Anything other than a “0"
programmed in this location will cause the AC and Low Battery restore codes to be sent to the central station. AC
Restore will be sent after the delay time programmed in location 623.
Location 377: Programming The Number Of Expansion Devices On The Buss Loop
This location is used to program the number of expansion devices added to the buss loop. DO NOT INCLUDE
KEYPADS IN THIS COUNT! The maximum number of expansion devices that can be added to the Ranger 9000
is seven, therefore the largest number that can be programmed in this location is "7". Factory default for this
location is "0".
Location 378: Communicator Code For Expansion Trouble
Location 378 contains the extended communicator code digit for
Expander Trouble
. The second digit, or zone
ID, of this report will be the number of the expansion device that is in trouble. The
Expander Trouble Restore
code is programmed in location 511.
Location 379: Phone Number To Report Expansion Trouble Code
Location 379 is used to select the phone number to report Expander Trouble. Program a "1" in this location to
report to phone #1 only. Program a "2" to report to phone #2 only. Program a "3" to report to both phone numbers.
If an "8" is programmed in this location, Expander Trouble will cause zone 32 to "open", and cause Expander
Trouble take on the reporting and alarm characteristics of zone 32.