30
Locations 380-395: Programming The Zone Types For Zones 17-32
Locations 380 through 395 contain a number identifying the
Zone Types
of zones 17 through 32. Location 380
corresponds to zone 17 and location 395 corresponds to zone 32. Each zone 17-32 has been factory defaulted
to a "6",
"Instant"
zone type. To program zone types other than the default values, program a number from "1"
to "9" based on the "Available Zone Types" table below.
DATA
AVAILABLE ZONE TYPES
"1"
DAY ZONE
- When armed, a trip produces an instant alarm. When disarmed, a trip activates the
keypad sounder.
"2"
24 HOUR
- A trip on a 24 Hour zone produces an instant alarm when armed or disarmed.
"3"
ENTRY/EXIT
- A trip will start entry delay. The lack of a trip during exit delay will enable the
Automatic Bypass or Instant mode if so programmed.
"4"
INTERIOR DELAY
- A trip on Interior Delay zone will initiate an entry delay. It will be ignored during
exit delay and when disarmed .
"5"
INTERIOR FOLLOWER
- Interior zone that follows the delay zones. It is instant during non-delay
times. It can be bypassed before arming, or by allowing it to automatically be bypassed in the
Automatic Bypass/Instant mode if so programmed.
"6"
INSTANT
- Produces an instant alarm if tripped when armed. Ignored when disarmed.
"7"
SECONDARY DELAY
- Like an Entry/Exit zone but has its own independent delay time.
"8"
FIRE
(PRIORITY WHEN AHJ HAS NOT APPROVED) - A short on a FIRE zone (non-bypassable)
will communicate to the central station when the Ranger 9000E is armed or disarmed. An open will
create a Trouble condition. Keypad LED will be steady for FIRE, and flashing for Trouble.
"9"
KEYSWITCH
- A zone attached to a momentary keyswitch will cause the Ranger 9000E to arm or
disarm when the zone is shorted. NOTE: Program the corresponding "Special Characteristics For
Zones 17-32"(locations 396-411) as a "0".
Locations 396-411: Assigning Special Characteristics For Zones 17-32
Locations 396 through 411 are used to assign
Special Characteristics
for zones 17 through 32. Location 396
corresponds to zone 17 and location 411 corresponds to zone 32. Each zone can have any or all of the following
characteristics regardless of the zone type selected in locations 380-395, excluding Fire zones which cannot have
bypass capability enabled. Factory default is "12" for each of these locations, meaning that
Zone Bypass
Capability & Entry-Guard
are enabled, and the other characteristics are not enabled. To include other
characteristics, add the values, and program the sum in the appropriate location. See the table below for zone
characteristics and their corresponding values.
VALUE
CHARACTERISTIC
1
Fast Loop Response
(200mS)
2
Group Bypass Zone
4
Entry-Guard Zone
8
Zone Bypass Capability
Example 1 -
To add
Group Bypass Zone (Value=2)
to
Zone
Bypass Capability (Value=8)
for zone 20 (location 399), add
the value of the two characteristics (2 + 8 ="10"), and program
the sum of "10" in location 399.
Example 2 -
To enable
ALL
characteristics for zone 20, add the
value of all characteristics (1 + 2 + 4 + 8 = "15"), and program
the sum of "15" in location 399 (zone 10 characteristics
location).
Example 3 -
To disable all characteristics and create a
Non
Bypassable Zone
, program a "0" in the appropriate location.