14
Locations 187-202: Special Communicator Reporting Characteristics For Zones 1-16
Locations 187-202 are used to assign communicator characteristics to individual zones 1 through 16. Location 187
is for zone 1 and location 202 is for zone 16. Each zone can have one or a combination of these characteristics.
Factory default for all zones is "11" (1 + 2 + 8 ="11"). This means that each zone has
Restore Reporting (Value=1
),
Bypass Reporting (Value=2)
, and
Report Canceling (Value=8)
enabled. It should be noted that these locations
are used to enable individual zone report capability by zone. A reporting code must be programmed in the
appropriate location to enable overall reporting capability of
Restore
reports (location 364), Bypass reports (Location
368),
Trouble/24 Hour Tamper
reports (location 372), and
Cancel
reports (location 354).
VALUE
REPORTING CHARACTERISTICS
1
Restore Reporting
2
Bypass Reporting
4
Trouble/24 Hour Tamper Reporting
8
Report Canceling
Location 203: Programming The Communicator To Abort
Location 203 is used to enable the communicator
Abort
. A "1" in this location will cause the Ranger 9000E to abort
the report of a trip on any non-24 hour zone, if an arm/disarm code is entered during the delay of line seizure (see
location 221). If this location contains a "0", the Ranger 9000E will not abort any reports. NOTE! The Ranger 9000E
will not abort unless a delay time is programmed in location 221.
Location 204: Immediate Restore By Zone
If a "1" is programmed in location 204, restoral signals will follow the restore condition and report restores
immediately after the condition has restored. A non-extended format will not send a
Restore
message until all zones
and
Trouble
conditions have restored. If this location contains a "0", the
Restore
signal(s) will be reported only after
siren timeout.
Location 205: Force Arm Enable
Location 205 is used to enable the
Force Arming
feature. If a "1" is programmed in this location, the Ranger 9000E
will allow the user to enter a valid code to arm, when one or more zones are not secure. If these zones clear before
the end of either exit delay, they will arm with the remainder of the zones when the exit delay time expires. All zones
which are unsecure at the end of the exit delay will be automatically bypassed. If bypass reporting has been enabled,
all automatically bypassed zones will be reported to the monitoring station.
Location 206: Programming For Silent Keypad Panic
Location 206 is used to silence the audible output for the
Keypad Panic/Hold-Up
alarm. Programming a "1" in this
location will enable the
Silent
mode of
Keypad Panic
operation. Factory default is "0" and operation of the
Keypad
Panic
(double keypress [
r
] & [#]) will cause the yelp siren output to activate.
Location 207: Priority (Fire) Siren Cutoff Inhibit
If a "1" is programmed in location 207, a Priority zone type siren will sound continuously until an arm/disarm code
is entered. If this location contains a "0", the Priority zone type siren will shutdown after the amount of time
programmed in location 138 has elapsed. Factory default is "0". Programming in this location does not affect the
burglary siren.