Error Messages
SCPI-Specific Error Messages
9.6
Operating Manual 1302.6163.12 - 03
-214
Trigger deadlock
The trigger source for the initiation of measurement is set to GET and subsequent
measurement is received. The measurement cannot be started until a GET is
received, but the GET would cause an interrupted-error)
-215
Arm deadlock
The trigger source for the initiation of measurement is set to GET and subsequent
measurement is received. The measurement cannot be started until a GET is
received, but the GET would cause an interrupted-error.
-220
Parameter error
The command contains a faulty or invalid parameter.
-221
Settings conflict
There is a conflict between setting of parameter value and instrument state.
-222
Data out of range
The parameter value lies out of the allowed range of the instrument.
-223
Too much data
The command contains too many data.
Example: The instrument does not have sufficient storage space.
-224
Illegal parameter value
The parameter value is invalid.
Example: The text parameter is invalid,
TRIGger:SWEep:SOURce TASTe
-230
Data corrupt or stale
The data are incomplete or invalid.
Example: The instrument has aborted a measurement.
-231
Data questionable
The measurement accuracy is suspect.
-240
Hardware error
The command cannot be executed due to problems with the instrument hardware.
-241
Hardware missing
Hardware is missing.
Example: An option is not fitted.
-250
Mass storage error
A mass storage error occurred.
-251
Missing mass storage
The mass storage is missing.
Example: An option is not installed.
-252
Missing media
The media is missing.
Example: There is no memory stick connected.
Error code
Error text in the case of queue poll
Error explanation
Содержание ESU Series
Страница 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual...
Страница 25: ......
Страница 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03...
Страница 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03...
Страница 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03...
Страница 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03...
Страница 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03...
Страница 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03...
Страница 821: ...R S ESU Remote Control Programming Examples More Complex Programming Examples 7 32 Operating Manual 1302 6163 12 03...
Страница 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03...
Страница 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU...
Страница 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03...