Operating Manual 1302.6163.12 - 03
6.295
R&S ESU
Remote Control – Description of Commands
Differences in GPIB Behavior between the FSP and the FSE Families of Instruments
R&S
ESU
FSE
CALCulate<1|2>:LIMit<1...8>:LOWer[:DATA] <numeric
value>
FSE
CALCulate<1|2>:LIMit<1...8>:MARGin
0 to 100DB
not available for
R&S ESU, FSET and
ESIB
R&S
ESU
FSE
CALCulate<1|2>:LIMit<1...8>:NAME
1 to 8|<string>
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
MODulation:EXCeptions?
ARFCn | TXBand |
RXBand| COMBined |
DCSRx1800
not available for
R&S ESU, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
MODulation:FAILs?
ARFCn | TXBand |
RXBand| COMBined |
DCSRx1800
not available for
R&S ESU, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
MODulation?
ARFCn | TXBand |
RXBand| COMBined |
DCSRx1800
not available for
R&S ESU, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
SWITching:FAILs?
not available for
R&S ESU, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPECtrum:
SWITching?
not available for
R&S ESU, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPURious:FAILs?
TXBand | OTXBand|
RXBand | IDLeband
not available for
R&S ESU, FSET and
ESIB
FSE
CALCulate<1|2>:LIMit<1...8>:SPURious?
TXBand | OTXBand|
RXBand | IDLeband
not available for
R&S ESU, FSET and
ESIB
R&S
ESU
FSE
CALCulate<1|2>:LIMit<1...8>:STATe
ON | OFF
R&S
ESU
FSE
CALCulate<1|2>:LIMit<1...8>:TRACe
1 to 3
R&S ESU: 3 traces are
available per screen
FSE: 4 traces are
available in full screen
mode and 2 traces per
screen in split screen
mode
R&S
ESU
CALCulate<1|2>:LIMit<1...8>:UNIT
DBM | DBPW | WATT |
DBUV | DBMV | VOLT |
DBUA | AMPere | DB |
DBUV_M | DBUA_M |
DEG | RAD | S | HZ |
PCT | UNITLESS
Available units are
compatible to the FSE
FSE/
FSIQ
CALCulate<1|2>:LIMit<1...8>:UNIT
DBM | DBPW | WATT |
DBUV | DBMV | VOLT |
DBUA | AMPere | DB |
DBUV_MHZ |
DBMV_MHZ |
DBUA_MHZ | |DBUV_M
| DBUA_M | DBUV_MHZ
| DBUA_MHZ | DEG |
RAD | S | HZ | PCT |
UNITLESS
only the following units
are available for the
R&S ESU:DBM | DBPW
| WATT | DBUV | DBMV |
VOLT | DBUA | AMPere |
DB | DBUV_M |
DBUA_M | DEG | RAD |
S | HZ | PCT |
UNITLESS
Devices
Command
(Sheet 7 of 47)
Parameter
Notes
Содержание ESU Series
Страница 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual...
Страница 25: ......
Страница 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03...
Страница 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03...
Страница 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03...
Страница 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03...
Страница 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03...
Страница 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03...
Страница 821: ...R S ESU Remote Control Programming Examples More Complex Programming Examples 7 32 Operating Manual 1302 6163 12 03...
Страница 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03...
Страница 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU...