WCDMA TPC Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
845
User Manual 1173.9657.02 ─ 11
mands of the signaling application. While the Standalone (SA) scenario is active, they
are configured via measurement commands.
The following table provides the mapping for TPC measurement commands. For gen-
eral measurement settings, see
Mapping for general measurement settings
Table 4-6: Mapping for TPC measurement commands
Setting
Commands for SA scenario
Commands for CSP scenario
TPC setup
CM pattern selection
not relevant
CM pattern
TPC alg. / step size
not relevant
RMC DL resource in
use
not relevant
TPC test step E to H
settings
4.6 List of Commands
ABORt:WCDMa:MEAS<i>:TPC.....................................................................................................................817
CALCulate:WCDMa:MEAS<i>:TPC:CARRier<c>:PSTeps:AVERage?.........................................................840
CALCulate:WCDMa:MEAS<i>:TPC:CARRier<c>:PSTeps:MAXimum?........................................................840
CALCulate:WCDMa:MEAS<i>:TPC:CARRier<c>:PSTeps:MINimum?......................................................... 840
CALCulate:WCDMa:MEAS<i>:TPC:CARRier<c>:TRACe:PSTeps:CURRent?............................................ 837
CALCulate:WCDMa:MEAS<i>:TPC:CARRier<c>:TRACe:UEPower:CURRent?.......................................... 836
CALCulate:WCDMa:MEAS<i>:TPC:CARRier<c>:UEPower:AVERage?...................................................... 838
CALCulate:WCDMa:MEAS<i>:TPC:CARRier<c>:UEPower:MAXimum?......................................................838
CALCulate:WCDMa:MEAS<i>:TPC:CARRier<c>:UEPower:MINimum?.......................................................838
CONFigure:WCDMa:MEAS<i>:TPC:CTFC:MLENgth................................................................................... 826
CONFigure:WCDMa:MEAS<i>:TPC:ILPControl:AEXecution........................................................................823
CONFigure:WCDMa:MEAS<i>:TPC:ILPControl:MLENgth?..........................................................................823
CONFigure:WCDMa:MEAS<i>:TPC:ILPControl:TSEF..................................................................................823
CONFigure:WCDMa:MEAS<i>:TPC:ILPControl:TSGH.................................................................................824
CONFigure:WCDMa:MEAS<i>:TPC:ILPControl:TSSegment........................................................................824
CONFigure:WCDMa:MEAS<i>:TPC:LIMit:CTFC.......................................................................................... 834
CONFigure:WCDMa:MEAS<i>:TPC:LIMit:ILPControl:MAXPower................................................................829
CONFigure:WCDMa:MEAS<i>:TPC:LIMit:ILPControl:MAXPower:ACTive?................................................. 830
CONFigure:WCDMa:MEAS<i>:TPC:LIMit:ILPControl:MAXPower:UDEFined.............................................. 831
List of Commands
深圳德标仪器