WCDMA TPC Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
837
User Manual 1173.9657.02 ─ 11
You can query the number of measured slots using the
CONFigure:WCDMa:MEAS:TPC:...:MLENgth?
command of the used measurement
mode.
Return values:
<Reliability>
<UEpower>
n power results, one per measured slot
Range:
-100 dBm to 55 dBm
Default unit: dBm
Example:
See
Usage:
Query only
Firmware/Software:
V3.2.70
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
CALCulate:WCDMa:MEAS<i>:TPC:CARRier<c>:TRACe:PSTeps:CURRent?
FETCh:WCDMa:MEAS<i>:TPC:CARRier<c>:TRACe:PSTeps:CURRent?
READ:WCDMa:MEAS<i>:TPC:CARRier<c>:TRACe:PSTeps:CURRent?
Return the values of the power steps trace per carrier.
Each power step is calculated as the difference between the UE power of a slot and
the UE power of the preceding slot. For the first measured slot a 0 is returned.
You can query the number of measured slots using the
CONFigure:WCDMa:MEAS:TPC:...:MLENgth?
command of the used measurement
mode.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Suffix:
<c>
.
1..2
Selects the carrier to be queried - only relevant for dual carrier
HSUPA
Return values:
<Reliability>
<PowerSteps>
n power step results, one per measured slot
Power step result number m indicates the difference between
the UE power results number m and number m-1. The first
power step result equals NCAP.
Range:
-50 dB to 50 dB
Default unit: dB
Example:
See
Usage:
Query only
Command Reference
深圳德标仪器
135-1095-0799