WCDMA Multi Evaluation Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
710
User Manual 1173.9657.02 ─ 11
FETCh:WCDMa:MEAS<i>:MEValuation:CARRier<c>:TRACe:RCDerror:SF:
EDPCch?
FETCh:WCDMa:MEAS<i>:MEValuation:CARRier<c>:TRACe:RCDerror:SF:
HSDPcch?
READ:WCDMa:MEAS<i>:MEValuation:CARRier<c>:TRACe:RCDerror:SF:
EDPCch?
READ:WCDMa:MEAS<i>:MEValuation:CARRier<c>:TRACe:RCDerror:SF:
HSDPcch?
Returns the current spreading factors for the E-DPCCH and the HS-DPCCH.
Each value refers to a half-slot or a full-slot, depending on the measurement period
(see
on page 653). The number of results depends on the measurement length (see
Suffix:
<c>
.
1..2
Selects the carrier to be queried - only relevant for dual carrier
HSUPA
Return values:
<Reliability>
<SF_1> ... <SF_n>
2 | 4 | 8 | 16 | 32 | 64 | 128 | 256
Spreading factors, one result per measured slot or half-slot
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.15.0
V3.2.60: command renamed (
CARRier<c>
added)
Options:
R&S CMW-KM401
R&S CMW-KM405 for dual carrier HSUPA
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
FETCh:WCDMa:MEAS<i>:MEValuation:CARRier<c>:TRACe:RCDerror:SF:
EDPDch<no>?
READ:WCDMa:MEAS<i>:MEValuation:CARRier<c>:TRACe:RCDerror:SF:
EDPDch<no>?
Returns the spreading factors for the E-DPDCH 1 to 4.
Each current value refers to a half-slot or a full-slot, depending on the measurement
period (see
on page 653). The number of results depends on the measurement length (see
Suffix:
<no>
.
1..4
selects the E-DPDCH for which the results shall be retrieved
Command Reference