WCDMA TPC Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
834
User Manual 1173.9657.02 ─ 11
<NomMaxPower>
Nominal maximum UE power
Range:
-47 dBm to 34 dBm
*RST:
24 dBm
Default unit: dBm
<UpperLimit>
Upper limit = nominal power + this value
Range:
0 dB to 10 dB
*RST:
1.7 dB
Default unit: dB
<LowerLimit>
Lower limit = nominal power + this value
Range:
-10 dB to 0 dB
*RST:
-6.7 dB
Default unit: dB
Example:
See
Firmware/Software:
V3.0.30
Manual operation:
See
CONFigure:WCDMa:MEAS<i>:TPC:LIMit:CTFC
<PowerStepLimit>,
<CalcBetaFactors>[, <PowerStepSize>]
Configures a power step limit for the measurement mode "Change of TFC".
Parameters:
<PowerStepLimit>
Symmetrical tolerance value for the power step size
Range:
0 dB to 10 dB
*RST:
2.3 dB
Default unit: dB
<CalcBetaFactors>
OFF | ON
Enables or disables the automatic calculation of the expected
power step size from the configured beta factors
*RST:
ON
<PowerStepSize>
Expected power step size applicable if the automatic calculation
from beta factors is disabled
Range:
0 dB to 24 dB
*RST:
7 dB
Default unit: dB
Example:
See
Firmware/Software:
V3.0.30
Manual operation:
See
Command Reference