WCDMA TPC Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
823
User Manual 1173.9657.02 ─ 11
CONFigure:WCDMa:MEAS<i>:TPC:ILPControl:MLENgth?
Query the number of slots measured in "Inner Loop Power Control" mode. The value
depends on the selected TPC setup and the test step settings.
It can only be determined while the "Inner Loop Power Control" mode is active. In other
modes INV is returned.
Return values:
<MeasLength>
Range:
101 slots to 341 slots
*RST:
INV
Default unit: slots
Example:
See
Specifying Additional Measurement-Specific Settings
Usage:
Query only
Firmware/Software:
V2.1.20
Manual operation:
See
CONFigure:WCDMa:MEAS<i>:TPC:ILPControl:AEXecution
<Enable>
Enables or disables automatic execution of the TPC setup for combined signal path
measurements in "Inner Loop Power Control" mode.
Parameters:
<Enable>
OFF | ON
*RST:
ON
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V2.1.20
Manual operation:
See
CONFigure:WCDMa:MEAS<i>:TPC:ILPControl:TSEF
<Length>, <Statistics>
Configures the inner loop power control test steps E and F.
This command is only relevant for the standalone scenario. For the combined signal
path scenario, use
Parameters:
<Length>
Number of TPC bits per test step
Range:
100 to 170
*RST:
120
<Statistics>
Number of slots at the end of test step E (F), where the mini-
mum (maximum) output power results are measured.
Range:
1 slot to 20 slots
*RST:
20 slots
Default unit: slots
Example:
See
Specifying Additional Measurement-Specific Settings