WCDMA TPC Measurement
R&S
®
CMW-KG4xx/-KM4xx/-KS4xx
826
User Manual 1173.9657.02 ─ 11
CONFigure:WCDMa:MEAS<i>:TPC:CTFC:MLENgth
<NrSteps>
Specifies the number of power steps to be measured per step direction (n up steps + n
down steps). A query returns the configured number of steps and additionally the
resulting measurement length.
Parameters:
<NrSteps>
Number of steps to be measured per direction
Range:
1 to 5
*RST:
5
Return values:
<MeasLength>
Number of slots to be measured
Range:
1 slot to 301 slots
*RST:
301 slots
Default unit: slots
Example:
See
Specifying Basic Measurement Settings
Firmware/Software:
V3.0.30
Manual operation:
See
4.5.3.4
Trigger Settings
The following commands define the trigger parameters.
TRIGger:WCDMa:MEAS<i>:TPC:CATalog:SOURce?
........................................................826
TRIGger:WCDMa:MEAS<i>:TPC:SOURce
....................................................................... 827
TRIGger:WCDMa:MEAS<i>:TPC:SLOPe
......................................................................... 827
TRIGger:WCDMa:MEAS<i>:TPC:THReshold
....................................................................828
TRIGger:WCDMa:MEAS<i>:TPC:DELay
.......................................................................... 828
TRIGger:WCDMa:MEAS<i>:TPC:TOUT
........................................................................... 828
TRIGger:WCDMa:MEAS<i>:TPC:MGAP
.......................................................................... 829
TRIGger:WCDMa:MEAS<i>:TPC:CATalog:SOURce?
Lists all trigger source values that can be set using
.
Return values:
<TriggerList>
Comma separated list of all supported values. Each value is rep-
resented as a string.
Usage:
Query only
Firmware/Software:
V2.1.20
Manual operation:
See
Command Reference