SECTION 4 PROGRAMMING IN HYGIENE MODE
4 - 21
slowly to increase the gas flow from the bottle until the ball start
to float up in the tube. At this point, the flow rate of the
regulator matches the flow rate of the sampling pump.
Again, the adjustable flow regulator calibration method allows a
better matching of the flow rate between the regulator and the
sampling pump of MiniRAE Plus. Therefore, it should provide
a slightly more accurate calibration result. The disadvantage of
this method is that the adjustable flow regulator is more
expensive.
C) Tee Connection method:
In order to match the flow rate between the fixed regulator and
the sampling pump, it is possible to insert a Tee connector
between the regulator and the MiniRAE Plus unit. The Tee
connector will allow the excessive gas from the regulator to flow
out through the third opening on the Tee connector. This
method will also improve the calibration result.