![RADVision Scopia XT5000 Series Скачать руководство пользователя страница 119](http://html2.mh-extra.com/html/radvision/scopia-xt5000-series/scopia-xt5000-series_installation-manual_3357770119.webp)
Important:
GLAN2 is available in selected models only. For more information, refer to
Between Scopia XT Series Models
Installing and Enabling Licenses which
Figure 74: Configuring IP addresses from the web interface
5. Set the fields as described in
Table 27: Configuring IP addresses
on page 119.
Table 27: Configuring IP addresses
Field Name
Description
MAC Address
This setting cannot be changed.
Automatic IP
Address
Set to
Yes
(default) if the system gets its IP address automatically.
Set to
No
if you must set up a public IP address in the IP address
field. The other fields in this page become configurable. This is
required, for example, if the XT Series is connected directly to the
Internet, without any address translation, or when other external
endpoints need to dial to this endpoint as an MCU.
To secure SIP connections using TLS certificates, your system
must have a static IP address, since the system generates the
certificate request using its IP address as the Common Name (CN).
For more information, see
Securing Connections to the XT Series
on page 140.
IP Address
If the system gets its IP address automatically, indicates the IP
address assigned to the system.
Otherwise, enter the system static IP address here.
Installation Guide for Scopia XT5000 Series Version 3.2
Initial Configuration | 119