Configuring IP Addresses
About this task
To place calls, the system supports either IPv4-only mode, or dual IPv4 and IPv6 mode.
HTTP, SNMP, and AT commands management occurs in IPv4 only, even if you set the system to
support dual mode. You can configure the IPv4 address manually or automatically.
Media streams in the same conference can be a mixture of IPv4 and IPv6.
Before you begin
If configuring from the endpoint, you must first enable advanced configuration, as described in
Maintaining the Scopia XT Series Locally from the Endpoint
on page 73.
Procedure
1. Access the general network settings, as follows:
• From the XT Series web interface, select
Administrator Settings > Networks >
Preferences > General
.
• From the endpoint's main menu, select
Configure > Network
.
Figure 73: Enabling IPv6 mode
2. Set the
Use IPv6
field to enable or disable IPv6 support.
3. From the web interface only, select
Save
.
4. Access the IP address settings, as follows:
• From the endpoint, select either
GLAN 1
or
GLAN 2
.
• From the web interface, select
Addresses
under
GLAN 1
or
GLAN 2
.
Installation Guide for Scopia XT5000 Series Version 3.2
Initial Configuration | 118