Setting the function of control inputs A
and B
The function of each control input can be set as needed. This is done in menus and .
The following functions can be set:
Setting
Function
= Off (factory setting)
= NC mode (potential-free opener contact)
= NO mode (potential-free closer contact)
= Pause mode
= Open (dead-man operation, e.g. for roller shutter switches)*
= Close (dead-man operation, e.g. for roller shutter switches)*
* only potential-free closer contacts for a roller shutter switch
Brief description of functions
= Off
The control input is switched off (factory setting). For example, a motion detector can
be switched off if needed, without having to disconnect it.
= NC mode
A potential-free opener contact (external sensor or motion detector) can be connected
to the control input.
= NO mode
A potential-free closer contact (external sensor or motion detector) can be connected
to the control input.