15
GB
Connecting a potential-free opener contact as per + 12 V (NC mode).
pink (6)
12 V
Control input
Potential-free
opener contact
Setting mode in menu or :
Switching signals:
OPEN - STOP- CLOSE - STOP...
Switching signal if menu is enabled:
OPEN (opening)
(Menu = Automatic closing)
NOTE
When connecting several motion detectors or sensors to this input, the switch contacts in this
mode
must be switched in series
.
Connecting a potential-free closer contact as per + 12 V (NO mode).
pink (6)
12 V
Control input
Potential-free
closer contact
Setting mode in menu or
or
or
or
or :
Switching signals:
OPEN - STOP- CLOSE - STOP...
Switching signal if menu is enabled:
OPEN (opening)
(Menu = Automatic closing)
NOTE
When connecting several motion detectors or sensors on this input, the switch contacts in this
mode
must be switched in parallel
.
Connecting an external sensor or motion detector