Setting the function of control inputs A
and B
Brief description of functions
3
= Pause mode
◆
The sliding unit can be arrested in its current position by pressing the key provided
for this (Pause key). This makes it possible to conveniently clean the sliding unit
and the door/window opening, for example. Control signals from other external
controls (manual transmitter, external sensor, motion detector etc.) are suppressed.
◆
Press the Pause key again to switch the Pause mode off.
Signals
◆
4 x
acoustic signals as soon as Pause mode is switched on or off.
◆
when Pause mode is active
NOTE
◆
When Push mode is activated (see page 33), Pause mode is switched off as
soon as the sliding unit is moved manually.
◆
If function „Automatic closing“ is active, the sliding unit is closed approx. 6
seconds after Pause mode is switched off.
4
= Open signal (closer contact)
and
5
= Close signal (closer contact)
These functions are used for connecting a roller shutter switch with potential-free closer
contacts or a control with comparable switching pulses.
Dead-man operation
The drive moves the sliding unit in the corresponding direction for as long as the signal
persists. If the signal lapses during the run the drive stops.
NOTE
As both control inputs
A
and
B
are used for the application both control
inputs should be configured accordingly.
◆
Control input
A
= mode 4 (open)
◆
Control input
B
= mode 5 (close)
Control inputs
A
and
B
do not both have to be set to mode and . If
the application can be implemented using only one control input, the second control input
can also be set to any other function.